Product No. Diameter Length(cm) Shaft Stiffness Tip form
42.01.10142 0.032" 150 Standard  Straight
42.01.10172 0.032" 150 Standard  Angled 
42.01.10143 0.032" 180 Standard  Straight
42.01.10173 0.032" 180 Standard  Angled
42.01.10145 0.032" 260 Standard  Straight
42.01.10175 0.032" 260 Standard  Angled
42.01.10148 0.035" 150 Standard  Straight
42.01.10178 0.035" 150 Standard  Angled
42.01.10149 0.035" 180 Standard  Straight
42.01.10179  0.035" 180 Standard  Angled
42.01.10232 0.035" 180 Standard  
42.01.10151 0.035" 260 Standard Straight
42.01.10181 0.035" 260 Standard Angled
42.01.10234 0.035" 260 Standard  
42.01.10154 0.038" 150 Standard Straight
42.01.10184 0.038" 150 Standard Angled
42.01.10237 0.038" 150 Standard  
42.01.10155 0.038" 180 Standard Straight
42.01.10185 0.038" 180 Standard Angled
42.01.10238 0.038" 180 Standard  
42.01.10157 0.038" 260 Standard Straight
42.01.10187 0.038" 260 Standard Angled
42.01.10240 0.038" 260 Standard  

Stainless Steel Guide Wires

The guidewire is intended for percutaneous access to peripheral vasculature. It may be used to selectively introduce and place catheters and other interventional devices into the peripheral vasculature. The device should only be used by physicians trained in percutaneous, intravascular techniques and procedures.

  • Wire Coil: Stainless Steel
  • Standard fixed core
  • Coating: None
0.032" Product No.
0.035"
0.038" Length (CM) Tip form
42.01.60000 42.01.60002 42.01.60004 45 Straight
42.01.60001 42.01.60003 42.01.60005 45 J
42.01.60006 42.01.60008 42.01.60010 60 Straight
42.01.60007 42.01.60009 42.01.60011 60 J
42.01.60012 42.01.60014 42.01.60016 70 Straight
42.01.60013 42.01.60015 42.01.60017 70 J
42.01.60018 42.01.60020 42.01.60022 150 Straight
42.01.60019 42.01.60021 42.01.60023 150 J

Hemostasis Valve Sets

The hemostasis valve set is designed to connect/insert a catheter/guidewire to facilitate the performance of surgery. The hemostasis valve is designed to be used as a conduit when interventional devices are inserted into the human vascular system. The guidewire insertion tool is used to facilitate the introduction of a guidewire into the hemostasis valve. It consists of an austenitic stainless steel tube connected to a hub made of polycarbonate. The torque device is used to manipulate the guidance of a guidewire in vascular territories.

  • Pressure resistance and good sealing valve to reduce blood loss
  • Various types to suit clinician's habits - 4 types are available, 2 main types are unique in China
  • 1)Double PTCA type: innovative operation (allows operator to insert two PTCA balloons or one balloon and one piece at the same time).
  • 2)Push-pull type (press to close and press to open).
  • 3)Another main type: a special Y valve customized for neurosurgeons (unique in China), has a short appearance of 2-3cm, popular among neurosurgeons. In the past, the Y valves used in neurosurgery department were from cardiac surgery and then replaced by doctors. This customized type saves surgery time and increases comfort.
Product No. Description
42.03.10000 Twist Y Connector
42.03.10001 Push Pull Y connector
42.03.10004 Y Click type
42.03.10005 Twist Y connector with 25cm extension line and stopcocks
42.03.10002 Push Pull Y connector with 25cm extension line and stopcocks
42.03.10006 Y Click type with 25cm extension line and stopcocks
42.03.10003 Push Pull Y connector with 45cm extension line and stopcocks
42.03.10012 Y Click type with 45cm extension line and stopcocks
42.03.10053 Hemostasis Valve Set (two valves)
42.03.10054 Push pull with Green

Transradial Access Sets for Intervention

The transradial introducer set is intended for the introduction of balloons, diagnostic and interventional catheters or other devices in radial artery access procedures.

  • Wire Coil: Stainless Steel
  • Standard fixed core
  • Coating: None
Click TYPE- Ter II
Nitinol core with SS spring core guidewire included
Product No. Size(Fr.) Length(cm) Nitinol Guidewire Introducer Needle
42.10.20205 5 7 0.018"*45cm Straight 21G*4.0cm
42.10.20206 5 10 0.018"*45cm Straight 21G*4.0cm
42.10.20207 5 11 0.018"*45cm Straight 21G*4.0cm
42.10.20209 6 7 0.018"*45cm Straight 21G*4.0cm
42.10.20210 6 10 0.018"*45cm Straight 21G*4.0cm
42.10.20192 6 11 0.018"*45cm Straight 21G*4.0cm
42.10.20212 7 7 0.018"*45cm Straight 21G*4.0cm
42.10.20213 7 10 0.018"*45cm Straight 21G*4.0cm
42.10.20214 7 11 0.018"*45cm Straight 21G*4.0cm

Catalog